AMS requires a particle accelerator, originally used in nuclear physics research, which limits its widespread use due to high costs and technical complexity.

Fortunately, UC Davis researchers have access to the Lawrence Livermore National Laboratory Center for Accelerator Mass Spectrometry (CAMS LLNL), one of over 180 AMS research facilities in the world.

accelerator mass spectrometry dating-72

Accelerator mass spectrometry dating

This process, called sputtering, separates neutral, as well as positive and negative ions from the sample surface.

The sample is held at a negative potential, and negatively charged ions are accelerated away from the sample, resulting in a beam of negative ions (Figure 2, below). The low energy (~5-10 ke V) diverging beam that leaves the ion source is accelerated, focused and transported to the accelerator by the injector system. Most AMS systems use sequential injection, a process that switches between stable and rare isotopes via the application of varying voltages to the electrically insulated vacuum chamber of the analyzer magnet.

To date (August 2016), about 8000 samples for radiocarbon dating have been analyzed on the new machine. The equipment was funded by the Knut and Alice Wallenberg Foundation and by the Swedish Research Council.

At present the performance of the SSAMS system is as follows: precision (for samples younger than 5000 radiocarbon years): ± 35 14C-years, maximum datable age: ca 45000 BP, minimum sample weight: ca 0.2 mg of organic material (ca 0.1 mg of carbon).

Adding the capability to measure other isotopes is possible. Negative carbon ions are drawn from a graphite sample by cesium-sputtering.

The ions are first sorted by a low-energy mass spectrometer, which selects ions of given mass and injects the ions into the accelerator.The result is that samples up to 1000 times smaller can be handled.The approach was tested in principle by 1977 and for archaeological operation by 1983.The emerging ions pass through a velocity selector, are again analyzed for mass, and pass to the detector.Velocity selection is attained by a magnetic field and an electric field that are orthogonal to one another and to the beam direction; they are adjusted so that no deflection takes place for ions of the desired velocity." data-width="600" data-height="300"Be ionized to the 3 charge state.AMS is distinct from conventional Mass Spectrometry (MS) because it accelerates ions to extremely high energies (millions of electron volts) compared to the thousands of electron volts in MS (1ke V=1.6×10C present a challenge to conventional MS due to their low natural abundance and high background levels.